Cell Ranger6.1, printed on 12/25/2024
In this tutorial, you will learn how to:
Note: This tutorial is written with Cell Ranger v6.1.2. Commands are compatible with previous versions, unless noted otherwise.
Once Cell Ranger is installed, you are ready to run the cellranger mkfastq pipeline. The cellranger mkfastq pipeline is a wrapper around Illumina’s bcl2fastq program for demultiplexing Illumina base call files (BCL). This means that bcl2fastq2 (version 2.20) is a dependency for this pipeline. As the bcl2fastq2 program is not bundled with Cell Ranger, see this Q&A article for installation guidance.
We call our working directory the yard. First make a directory in the /yard to run the analysis.
mkdir ~/yard/run_cellranger_mkfastq cd ~/yard/run_cellranger_mkfastq
For this tutorial, we use the tiny BCL data set described here. We use the wget command to download the Illumina run directory and the simple sample sheet.
wget https://cf.10xgenomics.com/supp/cell-exp/cellranger-tiny-bcl-1.2.0.tar.gz wget https://cf.10xgenomics.com/supp/cell-exp/cellranger-tiny-bcl-simple-1.2.0.csv tar -zxvf cellranger-tiny-bcl-1.2.0.tar.gz
Before building the cellranger mkfastq command, look closer at these files. Use the command cat (for "concatenate") to print the sample sheet to the screen.
cat cellranger-tiny-bcl-simple-1.2.0.csv
The output looks like this:
Lane,Sample,Index 1,test_sample,SI-P03-C9
This file tells the pipeline that the library "test_sample" was sequenced on lane 1 of the flow cell and indexed using the SI-P03-C9 index set. The Sample column is used as the prefix for naming output files. This prefix also serves as the sample id in later Cell Ranger pipelines. In this case the prefix/sample id is test_sample.
The run directory has the following directory structure. Use the tree command to print the directory structure to the screen.
tree -L 2 cellranger-tiny-bcl-1.2.0/
The output will look something like this:
cellranger-tiny-bcl-1.2.0 ├── Config │ ├── h35kcbcxy_Oct-20-16\ 15-51-48_Effective.cfg │ ├── HiSeqControlSoftware.Options.cfg │ ├── RTAStart.bat │ └── Variability_HiSeq_C.bin ├── Data │ └── Intensities ├── InterOp │ ├── ControlMetricsOut.bin │ ├── CorrectedIntMetricsOut.bin │ ├── ErrorMetricsOut.bin │ ├── ExtractionMetricsOut.bin │ ├── ImageMetricsOut.bin │ ├── QMetricsOut.bin │ └── TileMetricsOut.bin ├── RTAComplete.txt ├── RunInfo.xml └── runParameters.xml
Your data may look a little different than this depending on the sequencing
instrument used. Looking at the first few levels of directories is a good way to
check for completeness. If you do not see the RTAComplete.txt
,
RunInfo.xml
, and runParameters.xml
files, then it is likely that the
pipeline will fail. If any of these files are missing, contact your sequencing
provider and ask for the complete run directory.
If tree is not installed on your system, you can use ls to explore the run directory.
ls -altR cellranger-tiny-bcl-1.2.0/
Now that we have data in the working directory, you are ready to build the command to run cellranger mkfastq. When running any pipeline for the first time, it is helpful to run the command with the --help option to print the usage statement. This shows the proper command syntax, which flags are required or optional, and other necessary information to include.
cellranger mkfastq --help
The output looks similar to this:
/mnt/home/user.name/yard/apps/cellranger-6.1.2/bin cellranger mkfastq (cellranger-6.1.2) Copyright (c) 2021 10x Genomics, Inc. All rights reserved. ------------------------------------------------------------------------------- Run Illumina demultiplexer on sample sheets that contain 10x-specific sample index sets, and generate 10x-specific quality metrics after the demultiplex. Any bcl2fastq argument will work (except a few that are set by the pipeline to ensure proper trimming and sample indexing). The FASTQ output generated will be the same as when running bcl2fastq directly. ... Usage: cellranger mkfastq --run=PATH [options] cellranger mkfastq -h | --help | --version Required: --run=PATH Path of Illumina BCL run folder.
There are three arguments or inputs that are added to the cellranger mkfastq command: –-id, --run, and --csv.
The --id can be anything. It is used by the pipeline to name the output directory that Cell Ranger is going to create to run in. This directory is called a pipestance, which is short for pipeline instance.
The --run argument points to the Illumina run folder that contains the BCL files.
The --csv argument is a comma-separated value (CSV) file that describes how samples were indexed on the Illumina flow cell.
The CSV file must be formatted as a text file, Unicode (UTF-8) (no BOM) with Unix line-feed (LF) end-of-line markers. Sometimes Microsoft Windows or Mac OS add extra characters to the ends of lines or text encoding. To avoid parsing errors in the pipeline software, text editing programs, such as nano or TextWrangler (Mac OS), are better for creating sample sheets than Microsoft Excel.
Next build the command line using the paths to these data and run it. Be sure to edit the --run and --csv file paths in red.
cellranger mkfastq --id=tutorial_walk_through \ --run=/mnt/home/user.name/yard/run_cellranger_mkfastq/cellranger-tiny-bcl-1.2.0 \ --csv=/mnt/home/user.name/yard/run_cellranger_mkfastq/cellranger-tiny-bcl-simple-1.2.0.csv
The output looks similar to this:
/mnt/home/user.name/yard/apps/cellranger-6.1.2/bin cellranger mkfastq (cellranger-6.1.2) Copyright (c) 2021 10x Genomics, Inc. All rights reserved. ------------------------------------------------------------------------------- Martian Runtime - v4.0.6 ... Waiting 6 seconds for UI to do final refresh. Pipestance completed successfully! 2022-01-04 15:05:08 Shutting down. Saving pipestance info to "tutorial_walk_through/tutorial_walk_through.mri.tgz"
Run times vary based on the system resources, but it shouldn’t take more than a few minutes. Now go to the fastq_path directory.
cd /mnt/home/user.name/yard/run_cellranger_mkfastq/tutorial_walk_through/outs/fastq_path ls -1
The output looks similar to this:
H35KCBCXY Reports Stats Undetermined_S0_L001_I1_001.fastq.gz Undetermined_S0_L001_R1_001.fastq.gz Undetermined_S0_L001_R2_001.fastq.gz
The Undetermined FASTQ files here at this level contain sequences that were unable to be assigned to valid index.
Demultiplexed FASTQ files with valid sequencing indices are found under the directory named after the flow cell id, in this case 'H35KCBCXY'.
ls -1 H35KCBCXY/test_sample
The output looks similar to this:
test_sample_S1_L001_I1_001.fastq.gz test_sample_S1_L001_R1_001.fastq.gz test_sample_S1_L001_R2_001.fastq.gz
These outputs from the cellranger mkfastq pipeline serve as input to the cellranger count pipeline described in Running cellranger count.